Burnham Boiler 107877-01 Control Board
The Burnham Boiler 107877-01 Control Board is the OEM Sage2.3 boiler control for the K2 and Aspen family. It is a black control board marked Sage2.3 boiler control system, with a front panel carrying the POWER, FLAME, ALARM and RESET indicators and button. The Sage2.3 manages the whole sequence of operation: it reads the temperature sensors, runs the blower and ignitor, proves the flame, controls the gas valve, and drives the pumps and display. Because every safety function passes through this one board, a failing unit can produce confusing symptoms, which is why a technician should confirm supply voltage, fuses and sensor readings before condemning the control.
An orange warning label on the board states that it is a replacement control for the following models only: K2-080-180, K2WT-080-180 (A and B), K2FT-085-270, K2FTC-155, X-C080-180 B, K2WT-180M, K2WTC-135-180 and ASPEN-085-205. It also warns that boiler size and altitude must be selected using the display before operating, and that the instructions supplied with the control must be followed. Burnham publishes the 107877-01 as the Sage2.3 boiler control in its K2 service parts list.
Typical reasons to replace the board include a dead display, no response to a call for heat, repeating internal fault codes, or burn damage found at the terminals. After installing the board, set the correct boiler size and altitude before the first firing, confirm every wiring harness connector is seated, and run the boiler through a full cycle. Handle the board by its edges, keep it dry, and avoid static discharge during installation; a clean control cabinet, tight terminal connections and a verified ground extend the life of the new control and prevent repeat faults. Other K2 and Aspen sizes can need a different control, so confirm the model against the label list before ordering.
Key Benefits
- Sage2.3 Control: The 107877-01 is the Burnham Sage2.3 board that runs ignition, flame proving, gas valve and pumps on the listed models.
- Model List on the Label: The orange label names each K2, X-C and ASPEN-085-205 model it is approved for, so matching is straightforward.
- Front Panel Indicators: POWER, FLAME, ALARM and RESET indicators help confirm the state of the boiler during startup.
- Setup After Install: Boiler size and altitude are selected on the display, so the control is configured for the actual installation.
Common Questions
- Which models does this board replace?: The label lists K2-080-180, K2WT-080-180, K2FT-085-270, K2FTC-155, X-C080-180 B, K2WT-180M, K2WTC-135-180 and ASPEN-085-205.
- Do I need to set anything after installing it?: Yes. Boiler size and altitude must be selected using the display before the boiler operates.
- Does it fit every K2 and Aspen boiler?: No. It is for the models named on its label; other sizes can need a different control.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.