Burnham Boiler 108155-01 Flow Switch

Burnham Boiler 108155-01 Flow Switch

Burnham Boiler

  • $178.24


The Burnham Boiler 108155-01 DHW Flow Switch is the OEM domestic hot water flow switch for combi boiler systems. It is a white-bodied switch with a black cable lead ending in a white plug connector. Its job is simple and important: when someone opens a hot water tap, water begins to move through the DHW circuit, the switch closes, and the boiler control reads that closure as a hot water demand.

On a combi that signal sets the whole sequence in motion. The control gives DHW priority over space heating, energizes the DHW pump, and starts the ignition sequence so the heat exchanger can heat water on demand. When the tap closes the flow stops, the switch opens, and the burner shuts down after its post-purge. A switch that sticks open leaves the shower cold while the boiler idles, and a switch that sticks closed can make the burner start with no draw on the system. Scale, sediment and debris in the DHW circuit are the usual causes of a sluggish flow switch, so hard-water areas see these failures more often. The switch also has a defined minimum flow threshold, so very low tap flow or a clogged aerator can keep it open even when the boiler control and the switch are both healthy; rule out a restricted fixture before replacing the device.

Replace the 108155-01 when hot water on demand is missing or erratic and the control never registers a flow signal. Isolate and drain the DHW piping as required, install the new switch in the same flow direction as the original, reconnect the plug connector, and test with a hot water tap running. If the sensor on the hot water side is also suspect, it is a separate part, so check each device on its own before ordering. The switch is a dry contact device, so a multimeter check across the switch terminals with water flowing and then stopped quickly shows whether it opens and closes as it should. Check the DHW pump, the plate heat exchanger and any inlet strainer for debris at the same time, because restricted flow can mimic a failed switch and send the technician after the wrong part.

Key Benefits

  • Combi Hot Water Trigger: The switch tells the control a tap is open so the boiler can begin the DHW sequence the moment hot water is called for.
  • Enables DHW Priority: A good signal lets the control switch from space heating to DHW priority immediately.
  • Plug-In Lead: The black cable and white plug connector mate directly with the control harness.
  • OEM Part Number: Supplied under the Burnham number 108155-01 so the part matches the original device.

Common Questions

  • What does a DHW flow switch do?: It senses water moving through the domestic hot water circuit and signals the control to start a hot water demand.
  • What are the signs of a failed switch?: No hot water on demand, hot water that cuts out, or a burner that never starts when a tap is opened.
  • Is it the same as the DHW temperature sensor?: No. The flow switch senses movement; a separate temperature sensor measures water temperature.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.