Weil McLain 510-312-176 Draft Inducer Assembly

Carrier 312926-257 Pressure Switch

Carrier

  • $11.43


The Carrier 312926-257 Low Pressure Switch is a replacement low pressure safety switch identified by its Carrier part number for equipment service. The job of a low pressure switch is to guard the compressor. It senses refrigerant pressure and opens an electrical circuit when that pressure drops under the switch setting. The control then stops the compressor, which helps prevent it from running hot with too little refrigerant and too little oil coming back to it. When pressure recovers to the closing point, the circuit can be restored according to the equipment sequence.

Because several pressure switches in the same number family can look much alike while operating at different settings, the part number is the thing to hold firm on. Match 312926-257 to the unit parts list or to the tag on the failed switch, then compare the connection fitting, electrical leads and pressure ratings before installation. Do not substitute a switch simply because it threads or brazes into the same location. A setting that is too low gives away protection, and one that is too high can cause nuisance shutdowns that send you back to the same job repeatedly.

A tripped switch usually has a reason. Put gauges on the system and watch pressure as the unit starts. Check refrigerant charge and search for leaks, inspect filters and coils, confirm indoor and outdoor airflow, and look for restrictions at the drier or metering device. Test the switch electrically with its leads disconnected and compare the result with the measured pressure. Replace it when its contacts disagree with the conditions it is sensing. Follow refrigerant handling rules, protect the new switch from heat if brazing is involved, leak check the connection and run the system long enough to confirm stable pressures before closing the panels.

Key Benefits

  • Safeguards the Compressor: A functioning low pressure switch interrupts operation when pressure falls to an unsafe level for the compressor.
  • Part Number Matching: Ordering 312926-257 keeps the repair tied to the specified Carrier component and its intended operating behavior.
  • Targets a Common Control Fault: Replacing a switch with failed contacts or a leaking connection restores a reliable protective signal to the control.
  • Compact Service Item: A small switch can be the difference between a safe, protected system and one that is running without a vital check.

Common Questions

  • What does a low pressure switch protect against? It helps protect the compressor from operating with abnormally low suction side pressure, which can follow a refrigerant leak, airflow loss or restriction.
  • How do I know this is the right switch? Match 312926-257 to the equipment parts list or original tag and compare settings, fitting and wiring. Send us the model and serial number if you need help confirming.
  • Is a tripped switch always defective? No. Most often it is responding to a real system condition. Verify pressures and airflow first, and replace the switch only when testing shows it is not operating correctly.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.