Century Motors FB1106 Motor
The Regal Rexnord Century Motors FB1106 condenser fan motor is a 1 HP permanent split capacitor (PSC) motor designed for compatible commercial air conditioning and refrigeration equipment. Featuring dual-voltage operation at 208-230/460 VAC, this single-phase motor delivers 1075 RPM with a rated current of 7.6/3.8 amps.
Constructed with a NEMA 56Y frame, semi-enclosed housing, and ball bearings, this HVAC replacement fan motor supports dependable operation in demanding cooling applications. The resilient mounting base helps reduce vibration and operating noise, while reversible rotation accommodates clockwise and counterclockwise fan configurations.
The Century FB1106 PSC motor features a 5/8-inch diameter shaft for secure attachment of compatible fan blade assemblies. Its dual-voltage configuration provides installation flexibility when servicing existing HVACR equipment. Before installation, technicians should verify horsepower, voltage, amperage, rotational speed, mounting dimensions, shaft configuration, and capacitor requirements. Proper motor selection helps maintain condenser airflow, efficient heat transfer, and reliable cooling system performance.
Technical Specifications
|
Specification |
Details |
|---|---|
|
Manufacturer |
Regal Rexnord |
|
Brand |
Century Motors |
|
Model Number |
FB1106 |
|
Product Type |
Outdoor condenser fan motor |
|
Motor Type |
Permanent Split Capacitor (PSC) |
|
Horsepower |
1 HP |
|
Output Power |
0.75 kW |
|
Voltage |
208-230/460 VAC |
|
Phase |
Single phase (1PH) |
|
Frequency |
60 Hz |
|
Motor Speed |
1075 RPM |
|
Number of Speeds |
1 |
|
Full Load Amps |
7.6/3.8 A |
|
NEMA Frame Size |
56Y |
|
Enclosure |
Semi-enclosed / Open Air Over (OAO) |
|
Bearing Type |
Ball bearings |
|
Rotation |
Reversible (CW/CCW) |
|
Shaft Diameter |
5/8 inch |
|
Shaft Length |
4-1/2 inches (confirm before ordering) |
|
Shaft Type |
Keyed with flat |
|
Number of Poles |
6 |
|
Frame Material |
Rolled steel |
|
Mounting |
Resilient base |
|
Mounting Orientation |
Horizontal |
|
Run Capacitor |
17.5 MFD, 440 VAC |
|
Capacitor Included |
Yes |
|
Insulation Class |
B |
|
Thermal Protection |
Automatic |
|
Maximum Ambient Temperature |
60°C (140°F) |
|
Service Factor |
1.0 |
|
Overall Length |
12.83 inches |
|
Body Length |
8.33 inches |
|
Weight |
Approximately 30 lbs |
|
Certification |
UL Recognized, CSA |
|
UPC |
786674020284 |
|
Cross Reference |
Carrier HC52AL461, Kramer Trenton DD661, DD791 |
|
Application |
Outdoor condenser fans and refrigeration equipment |
Key Benefits
-
1 HP motor output: Provides dependable driving power for compatible commercial condenser fan assemblies.
-
Dual-voltage operation: Supports 208-230V and 460V single-phase electrical systems.
-
1075 RPM single-speed operation: Maintains consistent condenser airflow and heat dissipation.
-
Permanent split capacitor design: Supports dependable motor starting and running performance.
-
Ball bearing construction: Provides smooth shaft rotation and reliable operation.
-
Resilient base mounting: Helps reduce vibration and operating noise.
-
Reversible rotation: Accommodates clockwise and counterclockwise fan applications.
-
High-temperature design: Rated for ambient operating temperatures up to 140°F (60°C).
-
Automatic thermal protection: Helps protect motor windings against overheating.
-
Keyed shaft with flat: Provides secure attachment of compatible fan blade hubs.
-
Run capacitor included: Includes a 17.5 MFD, 440 VAC run capacitor.
-
OEM replacement compatibility: Supports select Carrier and Kramer Trenton condenser fan applications.
Common Questions
What is the Century FB1106 motor used for?
The Century FB1106 is an outdoor condenser fan motor designed for compatible commercial air conditioning and refrigeration equipment requiring a 1 HP, 1075 RPM, single-phase motor.
What capacitor does the Century FB1106 require?
The Century FB1106 uses a 17.5 MFD, 440 VAC run capacitor. Always verify the required capacitor rating against the motor nameplate before installation.
Does the Century FB1106 replace the Carrier HC52AL461 motor?
The FB1106 is listed as a replacement for the Carrier HC52AL461 motor. Verify electrical ratings, mounting dimensions, shaft configuration, and equipment compatibility before purchasing.
Does the Century FB1106 replace Kramer Trenton DD661 and DD791 motors?
The FB1106 is listed as a replacement option for compatible Kramer Trenton DD661 and DD791 applications. Confirm the original motor specifications and mounting requirements before installation.
Can the Century FB1106 operate on 460V three-phase power?
No. Although this motor supports 460V operation, it is a single-phase motor and is not designed for direct three-phase operation.
Is the Century FB1106 motor reversible?
Yes. The motor supports clockwise and counterclockwise rotation. Follow the manufacturer's wiring diagram to configure the correct rotational direction.
What is the difference between the Century FB1106 and FR1106?
The FB1106 features a resilient mounting base, while the FR1106 features a rigid mounting base and is recommended for compatible vertical mounting applications.
What should technicians check before replacing a condenser fan motor?
Technicians should verify horsepower, voltage, amperage, RPM, frame size, shaft dimensions, mounting configuration, rotation, and capacitor requirements. Inspecting the fan blade, electrical connections, and condenser airflow is also recommended.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.