Danfoss 193B-1701 Thermo Valve

Danfoss 193B-1701 Thermo Valve

danfoss

  • $330.42


The Danfoss 193B-1701 (also identified as 193B1701) is a heavyweight VTC511 thermic valve engineered for hydronic heating applications, specifically for solid fuel boiler protection. This 1 1/4" NPT thermal loading valve features a high 16.2 Cv flow coefficient, designed to maintain a consistent return water temperature. By ensuring the boiler reaches and stays above a specific thermal threshold, it effectively prevents condensation and flue gas precipitation, which are the primary causes of corrosion and soot buildup in the heat exchanger. This Danfoss thermo valve relies on a self-acting thermostatic element to modulate the bypass, requiring no external power or controllers. For technicians managing biomass or wood-fired systems, the VTC511 series is a standard for increasing combustion efficiency and protecting the integrity of the pressure vessel during the startup and operational cycles.

Key Benefits for Contractors

  • Boiler Longevity: Prevents "sweating" and low-temperature corrosion by stabilizing the return water temperature.
  • High Flow Performance: The 16.2 Cv rating allows for high-volume throughput with minimal pressure drop in 1 1/4" piping.
  • Maintenance Efficiency: Features a rugged design that allows for the replacement of internal thermostatic elements without total valve disassembly.
  • Self-Contained Operation: Operates independently of electronic sensors, reducing potential points of failure in the field.
  • System Optimization: Faster heat-up times reduce fuel consumption and decrease particulate emissions by reaching steady-state combustion sooner.

Common Questions

What is the purpose of the 16.2 Cv rating on this valve?
The Cv rating indicates the flow coefficient; a 16.2 Cv ensures that even in high-demand hydronic loops, the valve does not create significant flow restriction, maintaining system balance.

Is the Danfoss 193B-1701 compatible with both wood and pellet boilers?
Yes, this thermal loading valve is designed for solid fuel applications where maintaining a high return temperature is critical to prevent creosote and soot accumulation.

How do I determine if my VTC511 needs a new thermostatic element?
If the return water temperature fails to reach the specified setpoint or the boiler stays in bypass mode too long, the internal element may be scaled or fatigued and should be inspected.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.