Fireye MB-600S System

Fireye MB-600S System

  • $3,723.25


The Fireye MB-600S is a professional-grade multi-burner control system designed for the rigorous demands of industrial process heating, including ovens and furnaces. This 120VAC chassis serves as the central hub for flame safeguard protection, supporting up to four initial burners with the capacity to expand up to 20 individual burners via additional modules. Engineered for high-reliability combustion control, the system integrates a motherboard (MB-600M), relay board (MB-600R), logic module (MB-600L), and power supply (MB-600P) into a single compact unit. It features a fast 3-second flame failure response time and selectable pilot trial for ignition (PTFI) settings of 5, 10, or 15 seconds. This burner management system is compatible with UV7 flame scanners and flame rods, providing dynamic diagnostics that identify the exact burner causing a flame failure. With built-in purge modulation, valve leak testing, and four auxiliary inputs, the MB-600S ensures precise sequencing and safety for complex, multi-burner valve trains.

Key Benefits

  • Scalable Architecture: Native support for 4 burners, expandable up to 20 for large-scale industrial arrays.
  • Precise Diagnostics: Instantly identifies the specific burner responsible for a flame failure, reducing troubleshooting downtime.
  • Flexible Configuration: Onboard DIP switches allow for field-adjustable purge timing from 0 seconds to 60 minutes.
  • Robust Standards: UL recognized and FM approved for high-stakes industrial environments.
  • Integrated Logic: Consolidates sequence control, flame monitoring, and valve leakage detection into one module.

Common Questions

Can I use different types of flame sensors with this unit?
Yes, the MB-600S supports plug-in modules for UV, UV self-check, and flame rod rectification sensors, providing flexibility for gas or oil firing.

How do I configure the purge and ignition timing?
Timing is set via DIP switches located on the internal logic module. These allow for precise increments to meet specific process safety requirements.

What is the maximum electrical load for the fan and valves?
The fan motor contact is rated for 15 Amps resistive (1/2 HP inductive), while valve and alarm relays are rated for 10 Amps resistive.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question