Honeywell C6097A3004 Pressure Switch

Honeywell C6097A3004 Pressure Switch

  • $214.81


The Honeywell C6097A3004 Gas/Air Pressure Switch is an industrial-grade safety control engineered for precise monitoring of positive, negative, or differential pressure in combustion systems. This adjustable pressure switch features a range of 0.4 to 5 inches water column (WC) and utilizes a 1/2 inch NPT connection for seamless integration into commercial burner manifolds and HVAC air handling units. As the 8104116102 direct replacement, this unit ensures compliance with critical safety interlock requirements for gas-fired boilers and furnaces. The C6097A3004 single-pole double-throw (SPDT) circuitry provides reliable electrical switching to signal fuel shut-off valves or control logic during pressure drops or surges. Designed for heavy-duty service, this Honeywell combustion pressure switch maintains strict tolerances to prevent hazardous ignition sequences and ensure optimal fuel-to-air ratios in high-performance equipment.

Technical Specifications & Benefits

  • Versatile Sensing Capabilities: Supports differential pressure sensing for airflow proving or positive gas pressure monitoring.
  • Wide Adjustment Range: Field-adjustable setpoint from 0.4" to 5" WC allows for precise calibration based on specific equipment requirements.
  • Direct Compatibility: Engineered as a drop-in replacement for the Honeywell 8104116102, reducing downtime during field service.
  • Rugged Construction: Built to withstand the environmental demands of industrial combustion chambers and mechanical rooms.
  • Standardized Piping: Features a 1/2" NPT bottom connection for standard installation in gas trains.

Common Questions

Can the C6097A3004 be used for both air and fuel gas?
Yes, this switch is rated for use with natural gas, LP gas, and air, making it a versatile component for combustion safety strings.

How do you adjust the pressure setpoint on this model?
The setpoint is adjusted via a dial located under the cover, allowing technicians to set the trip point within the 0.4" to 5" WC range for accurate safety limit control.

Is the Honeywell C6097A3004 suitable for mounting in any orientation?
While these switches are robust, they are typically calibrated for vertical mounting. Installing in other orientations may result in a slight shift in the switching point due to the weight of the internal diaphragm.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question