Manitowoc Ice 000015209 Ice Thickness Probe

Manitowoc Ice 000015209 Ice Thickness Probe

  • $156.79


The Manitowoc Ice 000015209 Ice Thickness Probe is a critical sensor for maintaining specific bridge thickness and efficient harvest cycles in Indigo NXT, NEO, and Koolaire modular ice machines. Functioning as a conductivity-based sensor, this genuine OEM replacement part detects when ice buildup on the evaporator reaches the ideal 1/8-inch thickness, triggering the control board to initiate the harvest. Integrated with a washer for secure mounting, this probe prevents common service issues like ice machine not harvesting or thin, inconsistent cube production. Technicians should verify a 3/16-inch air gap between the probe face and the evaporator plate using a standard Allen wrench for precise calibration. Excessive scale or mineral deposits on the stainless steel tip can insulate the sensor, causing long freeze cycles or safety limit trips. Replacing a worn or fouled 000015209 ice thickness control ensures your commercial ice machine repair restores factory-spec bridge consistency and reduces unnecessary stress on the compressor.

Key Benefits
  • Precision Harvest Control: Accurately signals the control board to terminate the freeze cycle, ensuring uniform ice bridge thickness.
  • Broad Compatibility: Engineered for seamless integration with Manitowoc Indigo NXT and NEO series units, including models IYT0500A and iT1200.
  • Durable Construction: Features a high-grade stainless steel sensing surface designed to withstand the high-moisture environment of the evaporator compartment.
  • Optimized Efficiency: Prevents "long freeze" errors (E01) and "long harvest" errors (E02) by maintaining reliable electrical conductivity.
Common Questions

How do I adjust the ice thickness on my Manitowoc machine?
Locate the adjustment screw on the probe bracket. Turning the screw clockwise moves the probe away from the evaporator for a thicker bridge, while counter-clockwise moves it closer for a thinner bridge.

Why is my ice machine skipping the harvest cycle?
A fouled or misaligned ice thickness probe often fails to sense the ice. Clean the probe with a soft cloth and an approved descaler, and check for a broken wire leading to the control board.

What is the correct gap for the 000015209 probe?
The standard technician's bench setting is 3/16 inches (approx. 4.7mm). If the probe face is touching the evaporator or is too far away, the machine will fail to produce consistent cubes.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question