Raypak 006504F Gas Valve

Raypak 006504F Gas Valve

Raypak

  • $828.68


The Raypak 006504F Gas Valve is an essential OEM replacement component for maintaining precise manifold pressure in commercial and residential hydronic systems. This 24V modulating gas valve is engineered for natural gas pool heaters and boilers, featuring a 3/4 inch NPT connection and a factory-set output of 3.8" WC. As a critical part of the combustion control string, it ensures reliable ignition and consistent thermal output for models including the Raypak 0182, 0260, and 0333B series. The compact housing facilitates direct-fit replacement in tight cabinets, while the robust solenoid design provides high-cycle durability under demanding operational conditions.

For field technicians, the 006504F offers a streamlined solution for addressing common burner issues such as weak pilot flames, failure to main burner ignition, or erratic manifold pressures. This modulating natural gas valve is designed to integrate seamlessly with standard 24VAC control circuits, allowing for accurate fuel metering during the heating cycle. Utilizing original Raypak replacement parts ensures that the system maintains its original safety listings and performance efficiency, preventing the common calibration offsets associated with universal aftermarket alternatives.

Key Benefits:
  • Precise 3.8" WC Output: Factory-calibrated for natural gas to ensure optimal combustion efficiency.
  • Modulating Capability: Supports variable burner fire rates for improved temperature stability.
  • Standard 3/4" NPT Ports: Ensures high-flow capacity and compatibility with existing gas manifolds.
  • 24V AC Operation: Compatible with most standard HVACR and pool heater control boards.
  • OEM Engineering: Guaranteed direct-fit for Raypak 182, 260, 330, and 430 series units.
Common Questions:
  • Which Raypak models is the 006504F compatible with? This valve fits several Hi-Delta and Raytherm models, specifically within the 0182 through 0430 size range.
  • Can this gas valve be used with liquid propane? No, this specific part number is configured for natural gas (3.8" WC) and is not intended for use with LP conversion kits without proper re-calibration.
  • What are the symptoms of a failing 006504F valve? Common indicators include the burner failing to ignite despite a signal from the module, or the gas pressure dropping below the required 3.8" WC during high-fire demand.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS