Resideo R8184G4009 Oil Burner Control

Resideo R8184G4009 Oil Burner Control

  • $144.33


The Resideo R8184G4009 is a heavy-duty Protectorelay oil burner control designed for automatic, non-recycling management of intermittent ignition systems. Built for professional-grade reliability, this unit controls the oil burner, oil valve, and ignition transformer simultaneously upon a call for heat from a 24 Voc thermostat. It features a high-precision solid-state flame sensing circuit that works in tandem with a C554A Cadmium Sulfide (Cad Cell) flame detector to ensure safe combustion cycles.

For the service technician, the R8184G4009 includes a 45-second safety switch timing and a front-mounted LED lockout indication for rapid diagnostics. The integrated manual trip lever allows for immediate safety switch opening, ensuring a hard shutdown during system maintenance or component testing. This Tradeline model is versatile for field replacements, mounting easily on standard 4x4 junction boxes or directly onto the burner housing. With a temperature range of -40°F to 130°F and a full load rating of 7.4 Amps at 120Vac, it provides the robust electrical overhead required for demanding residential and light commercial oil heating applications.

Key Benefits
  • Enhanced Safety: The 45-second safety switch prevents fuel accumulation by shutting down the system if a flame is not established within the designated window.
  • Simplified Service: An on-board LED indicator clearly signals system lockout, while the manual trip lever provides a mechanical method to assure shutdown during maintenance.
  • Broad Compatibility: Replaces a wide range of older Honeywell oil primary controls including R4184D1027, R8184G1005, and R8184G1286.
  • Durable Construction: Rated for intermittent ignition duty with a solid-state flame sensing circuit that resists environmental interference.
Common Questions

What flame sensor is compatible with the R8184G4009?
This control requires a C554A Cadmium Sulfide Flame Detector (Cad Cell) to monitor the burner flame effectively.

Can this control be used with a 240V system?
Yes, the unit is rated for both 120Vac and 240Vac operation, with contact ratings of 7.4 Amps and 3.7 Amps respectively.

How do you reset the control after a lockout?
There is an external manual reset button on the safety switch; however, the cause of the lockout should be diagnosed by a professional before resetting.