Resideo S8610U3009 Pilot Module
The Resideo S8610U3009 is a universal intermittent pilot ignition module designed to provide complete ignition sequence control, flame monitoring, and safety shutoff for central furnaces and heating appliances. Engineered for versatile field replacement, this 24Vac control supports both single rod and dual rod flame sensing configurations. The module features selectable ignition trial times of 15 or 90 seconds, followed by a 5-minute delay on failed attempts with continuous retry logic. For varied application requirements, the prepurge is field-configurable to either 30 seconds or no prepurge. This HVAC furnace control board is compatible with 100% shutoff systems using Natural or LP gas and includes an integrated damper connection with an automatic vent damper plug. As a high-performance pilot ignition control, it simplifies service calls by replacing dozens of legacy Honeywell and competitive models, ensuring reliable gas valve control and flame rectification in demanding environments.
Key Technical Benefits
- Universal Compatibility: Replaces over 400 Honeywell and competitive pilot modules, reducing truck stock requirements.
- Configurable Timing: DIP switch settings allow for precise ignition trial time and prepurge adjustments to match OEM specifications.
- Flexible Sensing: Fully compatible with existing local or remote flame sensing setups.
- System Diagnostics: LED indicators provide real-time status and assist in rapid troubleshooting of flame signal or hardware faults.
- Multi-Fuel Support: Rated for use with both Liquid Propane and Natural Gas systems.
Common Questions
Can the S8610U3009 replace a module with a different trial for ignition time?
Yes, the module is configurable for 15-second or 90-second trials, making it a suitable replacement for most intermittent pilot systems, provided the safety timings align with the appliance requirements.
Does this module support systems with a vent damper?
Yes, the Resideo S8610U3009 includes a standard 6-pin plug for a vent damper. If no damper is used, the included jumper plug stays in place for standard operation.
How do I convert this from a single-rod to a dual-rod system?
The module automatically detects the sensing configuration based on the wiring of the 'Sense' terminal versus the 'Spark' terminal, allowing for seamless integration into either setup.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
QUESTIONS & ANSWERS
Have a Question?
Be the first to ask a question about this.