The Resideo S8701A1050 Direct Spark Ignition Control Module is an electronic DSI control designed to manage ignition sequencing, flame monitoring, gas control operation, and safety shutdown in compatible gas-fired HVAC and heating equipment.

The S8701A1050 configuration provides a 30-second pre-purge, followed by a 4-second trial for ignition with one ignition trial. It uses a two-rod flame-sensing configuration and includes an alarm terminal. The S8701 control family also incorporates pressure-switch input and fan relay functions as part of the burner operating sequence.

When replacing an existing gas furnace ignition control module, verify the complete part number, wiring terminals, ignition sequence, flame-sensing arrangement, pre-purge requirements, ignition trial timing, and appliance specifications. Terminal arrangements and operating sequences can vary between ignition controls, so replacement should not be determined by physical appearance alone.

Key Benefits

  • Manufacturer: Resideo
  • Part Number: S8701A1050
  • Control Type: Direct Spark Ignition (DSI) Control Module
  • Pre-Purge: 30 seconds
  • Trial for Ignition: 4 seconds
  • Ignition Trials: One
  • Flame Sensing: Two-rod configuration
  • Alarm Terminal: Included
  • Controls ignition sequencing and flame monitoring
  • Supports pressure-switch input and fan relay functions
  • Provides safety shutdown when proper ignition is not established
  • Designed for compatible gas-fired HVAC and heating equipment
  • Part of the Resideo replacement platform for applicable older S87 and S89 controls

Common Questions

What is the Resideo S8701A1050 used for?
The S8701A1050 is a direct spark ignition control module used to control the ignition sequence and monitor flame operation in compatible gas-fired appliances.

Does the S8701A1050 have a pre-purge cycle?
Yes. The S8701A1050 configuration has a 30-second pre-purge.

What is the trial-for-ignition time?
The S8701A1050 provides a 4-second trial for ignition with one ignition trial.

Does this ignition module use separate spark and flame-sensing rods?
Yes. The S8701A1050 uses a two-rod configuration.

Can the S8701A1050 replace an older Honeywell S87 or S89 module?
The S8701 family is designed as a replacement platform for applicable older S87 and S89 controls. However, always verify terminal configuration, ignition timing, flame-sensing method, and appliance requirements before replacement.

SEO Keywords

Resideo S8701A1050, direct spark ignition control, DSI ignition module, gas furnace ignition control module, Resideo ignition control

Common Search Questions

  • What does the Resideo S8701A1050 replace?
  • What is the trial-for-ignition time on the S8701A1050?
  • Is the S8701A1050 a two-rod direct spark ignition module?

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

S8701A1050 is the cross for S87K1008 

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question