Resideo S8801A1046 Ignition Control

Resideo S8801A1046 Ignition Control

  • $337.34


The Resideo S8801A1046 Ignition Control is a specialized direct spark ignition (DSI) module designed for low-voltage gas-fired applications, including furnaces, boilers, and commercial heating equipment. When replacing an older S89E1058, this module serves as the primary upgrade path, offering a critical 4-second lockout safety timing to prevent gas accumulation during failed ignition attempts. This unit requires an external high-voltage spark generator and utilizes advanced sensing circuitry to achieve a flame failure response time of 0.8 to 1.3 seconds at 5 µA. Engineered to meet UL 60730-1 and UL 60730-2-5 standards, it ensures precise control over the ignition sequence. For technicians troubleshooting intermittent lockout issues, the S8801A1046 provides a stable 24VAC control circuit interface, making it a reliable HVAC replacement part for maintaining system safety and operational efficiency in high-demand environments.

Key Benefits for Technicians:
  • Direct Cross-Reference: Engineered specifically as the functional replacement for the Honeywell S89E1058, simplifying field installations.
  • Rapid Flame Detection: Features a high-sensitivity circuit capable of detecting flame signals as low as 5 µA for industrial gas ignition safety.
  • Standardized Compliance: Fully certified under UL 60730 standards, ensuring the control logic meets modern safety requirements for gas-fired appliances.
  • Optimized Lockout Timing: The 4-second lockout window provides a rigorous safety margin, essential for preventing hazardous gas buildup in the combustion chamber.
Common Questions:

Is the S8801A1046 compatible with hot surface ignition systems?
No, this module is strictly designed for direct spark ignition (DSI) systems. It requires an external spark generator and will not operate a 120V or 24V hot surface igniter.

What are the power requirements for this ignition module?
The Resideo S8801A1046 operates on a 24VAC (60Hz) control circuit. Ensure your transformer has sufficient VA capacity to handle the module and the gas valve load simultaneously.

Can this replace a module with a longer lockout time?
While a shorter lockout time like 4 seconds generally increases safety, always verify the technical specifications and appliance manufacturer's requirements to ensure the burner remains stable during the trial for ignition.