Schneider Electric (Barber Colman) M1500A Valve Actuator

Schneider Electric (Barber Colman) M1500A Valve Actuator

  • $513.88


The Schneider Electric (Barber Colman) M1500A Valve Actuator is a high-performance non-spring return linear actuator designed for precise HVAC globe valve modulation. Built on the SpaceLogic Forta platform, this unit delivers a robust 337 lbf (1500 N) of seating force, making it an ideal choice for chilled water, hot water, and steam applications. Its versatile universal control capabilities allow for seamless integration into systems requiring floating or proportional signals, including 0-10Vdc, 2-10Vdc, and 4-20mA (with the included 500 Ohm resistor). The 2-10Vdc feedback signal ensures the controller receives accurate real-time positioning data, while the U-bolt mounting system simplifies installation on VB-7xxx, VB-8xxx, and VB-9313 valve bodies.

Engineered for the field technician, the M1500A features "One Touch" automatic stroke calibration, allowing it to adapt to various valve travel lengths between 3/8" and 2" without external tools. The brushless DC motor provides quiet, reliable operation and is protected by torque overload protection across the entire stroke. With a die-cast aluminum housing and a NEMA 2 rated cover, this 24V globe valve actuator is built for the rigors of mechanical rooms. The integrated manual override handle allows for manual positioning during commissioning or power loss, ensuring the proportional control signal matches system flow requirements exactly.

Key Benefits

  • Multi-Signal Compatibility: Supports floating or proportional inputs (0-10V, 2-10V, 4-20mA) for maximum valve actuator wiring flexibility.
  • Field Selectable Logic: DIP switches allow for easy adjustment of direct or reverse action and flow curve selection (linear or equal percentage).
  • Robust Performance: Provides 337 lbf of force to maintain tight shut-off in high-differential pressure globe valve applications.
  • Fast Installation: The U-bolt tall mount design and self-calibrating stroke reduce labor time during HVAC valve replacement.

Common Questions

How do I calibrate the M1500A after installation?
Simply use the "One Touch" calibration switch on the circuit board. The actuator will automatically travel the full length of the valve stroke to learn the end-stop positions and scale the input signal accordingly.

Can this actuator replace older Barber Colman or Schneider models?
Yes, the M1500A is the current HVAC actuator replacement for many legacy Forta series units. Use the U-bolt mount for VB-8xxx/9xxx valves or the appropriate linkage kit for VB-7xxx series bodies.

Is a separate resistor required for 4-20mA control?
The M1500A is usually supplied with a 500 Ohm resistor to convert the 4-20mA current signal into a 2-10Vdc voltage signal for the internal processor.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question