Schneider Electric (Viconics) S3010W1031 Sensor

Schneider Electric (Viconics) S3010W1031 Sensor

  • $60.87


The Schneider Electric (Viconics) S3010W1031 is a high-precision wall mount temperature sensor engineered for seamless integration with Viconics VT8300 and VT8600 series room controllers. For contractors managing complex HVAC zones, this unit leverages a 10K Ohm Type 2 NTC thermistor to provide consistent resistance-based feedback to the BAS (Building Automation System). Its low-profile ABS thermoplastic enclosure is designed for durability in high-traffic commercial environments, supporting a wide humidity tolerance of up to 95% non-condensing. A key technical advantage for field techs is the internal DIP switch configuration, which allows for advanced temperature averaging by wiring multiple sensors in parallel. This eliminates localized hot or cold spots in large open-plan offices or retail spaces. Whether you are performing a Viconics sensor replacement or commissioning a new EcoStruxure project, the S3010W1031 ensures reliable remote room sensing with a 10K-2 output signal that is widely compatible across various HVAC automation platforms.

Key Benefits for Contractors:
  • Precise 10K Ohm Type 2 NTC: Delivers stable and accurate room temperature monitoring without the drift associated with lower-grade components.
  • On-Board Averaging Logic: Integrated DIP switches allow for 2 or 3 sensor averaging without requiring external logic modules.
  • Universal Compatibility: Optimized for use with Schneider Electric and Viconics room controllers, including the VT7000 and VT8000 families.
  • Rugged Enclosure: The standard 3.39" x 4.92" footprint covers existing wall penetrations for a professional, clean finish.
Common Questions:
  • Can I use this for temperature averaging? Yes. By adjusting the internal DIP switches, you can wire multiple S3010W1031 units together to report an average value to the master controller.
  • Does this require a separate power supply? No. It is a passive resistance sensor that draws detection current directly from the HVAC controller input.
  • What is the recommended mounting height? Technical best practice is to install the wall mount sensor approximately 5 feet (1.5 meters) above the finished floor on an interior wall to avoid false readings from drafts or thermal gain.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question