Superior Radiant VE007 Pressure Switch

Superior Radiant VE007 Pressure Switch

  • $89.41


The Superior Radiant VE007 Pressure Switch is a critical safety component engineered for infrared tube heaters and high-performance HVAC pneumatic systems. As a veteran-grade differential air pressure switch, the VE007 is designed to verify proper blower operation and vent airflow before allowing the ignition sequence to commence. This OEM pressure switch features a rugged diaphragm and precise electrical contacts to ensure a reliable differential pressure set point, preventing combustion in the event of blocked flue pipes or failed inducer fans. Primarily utilized in Superior Radiant Products (SRP) heating units, this air pressure sensing switch is a direct replacement part that maintains the operational integrity of commercial and industrial radiant systems. Its compact design facilitates straightforward installation in tight burner boxes, while its UL and CE certifications confirm it meets rigorous industrial safety standards for high-demand environments. Ensure your combustion air proving circuit is fully functional by utilizing this exact-spec Superior Radiant VE007 for your next service call or equipment overhaul.

Key Benefits
  • Combustion Safety Proving: Accurately detects sufficient airflow to prevent hazardous ignition during mechanical failure or venting obstructions.
  • Direct OEM Compatibility: Engineered specifically for Superior Radiant Products infrared heaters, ensuring a perfect fit and consistent differential pressure response.
  • Durable Construction: Built with high-grade diaphragm materials to withstand the thermal cycling and environmental demands of industrial heating cabinets.
  • Precise Electrical Switching: Features reliable internal contacts that integrate seamlessly into 24V or line-voltage control strings for immediate system feedback.
Common Questions

How do I verify if the VE007 is the cause of an ignition failure?
Using a manometer, check the actual differential pressure at the switch ports during the inducer pre-purge. If the pressure exceeds the switch set point but the contacts remain open, the VE007 pressure switch requires replacement.

Can this switch be used in systems other than infrared heaters?
While designed for SRP infrared units, this differential air switch is compatible with any HVACR application requiring air pressure verification, provided the set point and electrical ratings align with the manufacturer's original specifications.

What are the symptoms of a failing air pressure switch?
Common indicators include the heater failing to leave the pre-purge cycle, "pressure switch stuck open" error codes on the ignition module, or intermittent operation during high-wind conditions affecting the flue.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.