Utica-Dunkirk 11201007000136 Sensor/Thermistor

Utica-Dunkirk 11201007000136 Sensor/Thermistor

  • $5.90


The Utica-Dunkirk 11201007000136 Outdoor Pipe Temperature Sensor / Thermistor is a critical OEM component engineered for high-precision thermal monitoring in hydronic and HVAC systems. As a veteran-grade HVAC replacement sensor, this thermistor provides real-time resistance-based data to the control board to manage modulation and prevent freezing or overheating. Designed specifically for external piping applications, the 11201007000136 thermistor ensures accurate delta-T calculations, maintaining the performance curve of the boiler or heat pump. This Outdoor Pipe Temp Sen/Thermist is a direct replacement for failed NTC sensors that cause system short-cycling or outdoor reset errors. By utilizing a genuine Utica-Dunkirk part, contractors ensure the thermistor’s ohm rating matches the factory control board’s logic perfectly, eliminating the calibration drift common with universal alternatives. Precise outdoor temperature sensing is essential for optimizing fuel efficiency and protecting the compressor or heat exchanger from extreme thermal stress.

Key Benefits for the Field

  • OEM Resistance Curve: Matches factory control specifications for immediate, "plug-and-play" integration without recalibrating the board.
  • High-Accuracy NTC Element: Provides rapid thermal response to pipe temperature changes, allowing for tighter modulation control.
  • Industrial Build Quality: Encapsulated to withstand moisture infiltration and vibration common in outdoor condensate and refrigerant lines.
  • System Protection: Critical for sensing low-temperature conditions that trigger freeze protection cycles in hydronic loops.
  • Restored Efficiency: Corrects erroneous outdoor reset readings that lead to excessive fuel consumption or improper heating curves.

Common Technical Questions

What are the symptoms of a failed 11201007000136 thermistor?
Technicians typically see "Open" or "Short" sensor error codes on the display. In the field, you may notice the system failing to enter outdoor reset mode or the boiler running at high-limit temperatures regardless of the outdoor ambient conditions due to incorrect resistance feedback.

Does this sensor require polarity-sensitive wiring?
No, as a standard two-wire thermistor, polarity is not a factor. However, ensuring a clean, corrosion-free contact on the pipe surface and using the correct thermal paste is recommended for the most accurate readings.

Can this be used on both supply and return outdoor piping?
Yes, provided the system specifies the 11201007000136 part number for those positions. It is designed to monitor surface temperatures on copper or stainless steel piping in exposed environments.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS