Wayne Combustion 62378D Burner
The Wayne Combustion 62378D HSG200 Gas Conversion Burner is a high-static-pressure power gas burner designed for residential and light commercial heating applications, including oil-to-gas conversions of compatible furnaces and boilers.
This Wayne HSG200 gas burner features a 9-inch air tube, 4-inch outside tube diameter, and an adjustable mounting flange with a maximum insertion depth of 8 inches.
With a 60,000–200,000 BTU/hr firing range, the burner supports natural gas and LP propane operation through proper orifice selection, gas pressure adjustment, and combustion air settings. The burner is factory configured for natural gas and includes orifices for approved firing adjustments.
This Wayne 62378D oil-to-gas conversion burner uses direct spark ignition, electronic flame supervision, and a redundant gas valve. The 120V, 60Hz configuration is suitable for properly matched heating equipment.
A qualified technician must verify combustion chamber dimensions, appliance input rating, draft conditions, gas supply, and venting requirements before installation.
Technical Specifications
|
Specification |
Details |
|---|---|
|
Manufacturer |
Wayne Combustion Systems |
|
Part Number |
62378D |
|
Model |
HSG200 |
|
Product Type |
Gas Conversion Power Burner |
|
Air Tube Length |
9 inches |
|
Air Tube Diameter |
4 inches OD |
|
Maximum Tube Insertion |
8 inches |
|
Firing Range |
60,000–200,000 BTU/hr |
|
Fuel Type |
Natural Gas or LP Propane |
|
Electrical Supply |
120V, 60Hz |
|
Ignition |
Direct Spark, 7,300V |
|
Gas Connection |
3/4-inch NPT |
|
Mounting |
Adjustable Flange and Gasket |
|
Approximate Shipping Weight |
33 lb |
Key Benefits
-
60,000–200,000 BTU/hr firing capacity for compatible heating equipment.
-
9-inch air tube with adjustable mounting flange for installation flexibility.
-
Supports natural gas and LP propane operation with proper configuration.
-
High-static-pressure combustion design for demanding furnace and boiler applications.
-
Direct spark ignition with electronic flame supervision.
-
Suitable for select oil-to-gas furnace and boiler conversions.
-
Includes mounting flange, gasket, and gas orifice assortment.
Common Question
Can the Wayne 62378D HSG200 burner convert an oil-fired boiler to natural gas?
Yes, the HSG200 is designed for oil-to-gas conversions of compatible heating equipment.
However, the appliance must be suitable for conversion, and its input rating must fall within the burner's 60,000–200,000 BTU/hr firing range.
A qualified combustion technician must verify the combustion chamber, draft, venting, gas supply, and applicable installation codes before installation.
Common Search Questions
1. What is the BTU firing range of the Wayne HSG200 62378D gas conversion burner?
The specified firing range is 60,000–200,000 BTU/hr.
2. Can the Wayne 62378D HSG200 burner operate on propane gas?
Yes. The burner supports LP propane when equipped with the correct orifice and properly adjusted for the fuel.
3. What is the maximum insertion depth of the Wayne HSG200 9-inch burner tube?
The specified maximum insertion depth is 8 inches.
Disclaimer
While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
This item is not eligible for free shipping.
QUESTIONS & ANSWERS
Have a Question?
Be the first to ask a question about this.