Weil McLain 633-600-012 Service Pack

Weil McLain 633-600-012 Service Pack

Weil McLain

  • $129.60


The Weil McLain 633-600-012 AcuTemp 2000WM Service Pack is the OEM service kit for the AcuTemp temperature control used on Weil-McLain Aqua Plus and Aqua Pro indirect water heaters. The control mounts on the top plastic cap of the tank, reads the tank through a sensor and tells the boiler or zone control when the tank needs heat by closing a set of isolated dry contacts on the domestic water input. A built-in microcontroller watches how fast the tank temperature is changing and decides when to start a heat call, which cuts down temperature swings and improves fuel efficiency compared with a plain aquastat. Weil-McLain also supplies the AcuTemp 2000WM control without a sensor as the 633-600-011, so match the number to what the tank actually needs.

Electrically the AcuTemp is simple. It needs a field-supplied 24 VAC transformer, draws 2.4 VA at 60 Hz, and switches isolated dry contacts rated 50 VA at 24 VAC that land on the domestic water input of the zone or boiler control. To keep stray voltage off the sensor circuit, 24 VAC goes to AC2 and AC1 is grounded, and you should read 24 VAC between AC1 and AC2 before blaming the control. Settings are made at the dial: press it once and the display shows OFF or the current setpoint, turn it to change the value, and after five seconds without input it drops back to operating mode. Two ranges are built in, a residential range of 60°F to 160°F and a commercial range of 60°F to 180°F, and the Fahrenheit or Celsius display is chosen by holding the dial for five seconds. A light at the bottom right of the display shows a call for heat and a light on the left shows standby once the tank reaches setpoint. The differential never needs adjusting because the control's own algorithm decides when to start a heat call.

Installation follows the tank. On a new installation, find the sensor leads on top of the tank, run the sensor wire through the opening in the back of the control, plug it into the sensor input (polarity does not matter), seat the wire in the channel on the back, and fasten the control to the plastic cap with two screws plus a third through the top before the cover goes back on. When replacing an Aqua Plus control, remove the faceplate, the old thermostat and the old sensor, disconnect the domestic water input wires, insert the new sensor, pass both wires through the faceplate hole and remount with three screws. Weil-McLain publishes wiring diagrams for AquaBalance controls and for the ECO, Evergreen, Slimfit, Ultra, GV90+, CGa, CGi, EG water and WM97+ boiler lines. The displayed temperature is approximate because a tank always has temperature variation inside it, so start near 120°F and finish the adjustment by testing water at the closest point of use. Water at 125°F or hotter can scald, and a mixing valve is recommended wherever point-of-use water reaches that level. A Sensor Error means the sensor resistance is out of range, so check the connection at the circuit board and replace the sensor if the connection is good. A Self Test Error means an internal check failed, so cycle the 24 VAC power off and on and replace the control if the error stays.

Key Benefits

  • Smarter Heat Calls: The microcontroller tracks how fast the tank temperature moves and starts heat calls to reduce swings and save fuel.
  • Built For Weil-McLain Tanks: Made for Aqua Plus and Aqua Pro indirect water heaters and documented with wiring for the ECO, Ultra, GV90+, WM97+ and other Weil-McLain boiler lines.
  • Easy Field Setup: One push dial sets temperature, switches Fahrenheit and Celsius and selects the residential or commercial range.
  • Clear Diagnostics: Sensor Error and Self Test Error messages plus the call for heat and standby lights make troubleshooting quick.

Common Questions

  • Which water heaters does it fit? It is the AcuTemp control for Weil-McLain Aqua Plus and Aqua Pro indirect water heaters. Check the control already on the tank before ordering.
  • What power does it need? A field-supplied 24 VAC transformer. The control draws 2.4 VA and its dry contacts are rated 50 VA at 24 VAC.
  • What temperature should I set? Start near 120°F, then test at the point of use. Use a mixing valve if the water reaches 125°F or more.