York S1-024-35706-002 Motor

York S1-024-35706-002 Motor

  • $1,121.39


The York S1-024-35706-002 is a high-performance 1 HP blower motor designed specifically for York, Luxaire, and Coleman air handlers and furnaces. Operating at 208-230Vac and rated for 1050 RPM, this is a factory-programmed ECM blower motor, meaning the torque and airflow profiles are pre-configured to match OEM static pressure requirements. Unlike standard PSC motors, this programmed ECM motor modulates power consumption to maintain consistent CFM, improving overall system efficiency and reducing component stress. For technicians performing a field swap, verify the harness connector pins and mounting belly band diameter before installation. This HVAC blower motor provides the necessary lift for high-static applications and serves as a direct drop-in for worn or seized OEM units. Integrating the S1-024-35706-002 replacement ensures the internal logic of the control board aligns with the motor's performance curve, preventing common airflow faults during heating and cooling cycles.

Key Benefits

  • OEM Logic Integration: Pre-programmed with specific torque curves for York and Coleman air handlers.
  • High-Efficiency Output: 1 HP ECM design significantly reduces amp draw compared to standard induction motors.
  • Precision Airflow: Maintains 1050 RPM to ensure consistent humidity control and heat exchange.
  • Direct Technical Fit: Designed for 208-230V applications, eliminating the need for complex field modifications.

Common Technical Questions

How can I diagnose a control module failure on this motor?
Verify that the motor is receiving 230V line voltage and the proper 24V or PWM signal from the board. If the shaft is free-spinning but the motor does not engage, the integrated ECM control module has likely failed.

Does this motor require a capacitor?
No, as a programmed ECM motor, the S1-024-35706-002 uses internal electronics to handle phase conversion and does not utilize an external run capacitor.

Can this motor be used in 115V systems?
No, this unit is rated specifically for 208-230Vac. Attempting to run this motor on 115V will cause terminal damage to the electronic module.