York 025-28678-113 Transducer
The York 025-28678-113 Transducer is a precision-engineered OEM replacement part designed for high-accuracy pressure monitoring in commercial HVACR systems. Specifically utilized as an evaporator transducer, this component operates within a calibrated range of 50 to 125 PSI, converting mechanical pressure into a linear 0.5 to 4.5 VDC output signal. Built for the rigors of industrial chiller environments, it provides the critical data necessary for the microcomputer control center to maintain optimal refrigerant cycles and prevent evaporator freeze-up. Its robust design features a water-tight connector housing, ensuring signal integrity in high-moisture environments common to indoor and outdoor chiller units. When replacing field units, technicians should verify the interface compatibility, as this pressure sensor is foundational for precise HVAC system diagnostics and pressure regulation. This genuine York transducer ensures that system parameters remain within design specifications, supporting overall chiller efficiency and operational stability.
Key Benefits for Technicians:- OEM Precision: Direct replacement ensures seamless integration with existing York control logic without the need for field recalibration.
- Enhanced Durability: Equipped with water-tight connectors to prevent moisture ingress and signal drift in demanding environments.
- Linear Signal Output: Features a reliable 0.5-4.5 VDC range for accurate real-time pressure monitoring by the system controller.
- Critical Protection: Provides accurate tracking for 50/125# pressure ranges, essential for maintaining suction pressure safety limits.
- Is this transducer compatible with older York chillers? Yes, while newer units use water-tight connectors, this part can be integrated into older systems using a field conversion kit to update the interface.
- Where is this transducer typically located in the system? It is most commonly installed on the evaporator side to monitor suction or evaporator pressure.
- Can I use a universal 0-5V transducer instead? It is not recommended. The York 025-28678-113 is specifically offset for 0.5-4.5 VDC to provide precise error detection and signal scaling for York controls.
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.