York S1-324-36074-347 Motor

York S1-324-36074-347 Motor

  • $2,068.32


The York S1-324-36074-347 is a precision-engineered 3/4HP ECM Programmed Motor factory-calibrated for specific airflow requirements in York, Coleman, and Luxaire HVAC platforms. This electronically commutated motor features an integrated control module, serving as the direct replacement for S1-024-31947-004. By utilizing programmable blower motor technology, this unit maintains constant CFM against varying static pressures, ensuring industrial-grade efficiency and peak heat exchanger performance. As an OEM York furnace motor, it eliminates the compatibility risks associated with generic aftermarket parts, providing the exact torque and RPM profiles required for N1VSC1606A and N1VSC1606G series units. The dual-voltage capability supports 120V and 240V applications, with specific pin-jumper configurations for voltage selection. For technicians in the field, this programmed ECM blower motor simplifies the restoration of variable-speed functionality, ensuring reliable communication with the existing furnace control board and thermostat signals.

Key Benefits
  • Optimized Efficiency: Advanced ECM technology significantly reduces power consumption compared to standard PSC motors.
  • Plug-and-Play Integration: Pre-programmed module ensures the motor recognizes system-specific torque limits and ramp speeds immediately upon installation.
  • Precision Airflow: Maintains consistent CFM to prevent coil freeze-up and maximize dehumidification during cooling cycles.
  • Direct OEM Fit: Precise mounting and harness alignment for S1-024-31947-004 replacements, reducing downtime on the job site.
Common Questions

Is the module included with the motor?
Yes, the York S1-324-36074-347 comes as a complete assembly with the programmed control module factory-installed and tested.

Does this motor require field programming?
No, this unit is a programmed ECM motor that arrives with the specific software parameters required for its compatible York/Coleman air handler or furnace models.

What is the primary cause of ECM motor failure?
Most failures occur in the module due to voltage surges or excessive static pressure. It is recommended to check the blower wheel for debris and ensure the ductwork is sized correctly during replacement.

This item is not eligible for free shipping.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question